Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Surv Ophthalmol ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38492584

RESUMO

Artificial Intelligence (AI) has become a focus of research in the rapidly evolving field of ophthalmology. Nevertheless, there is a lack of systematic studies on the health economics of AI in this field. We examine studies from the PubMed, Google Scholar, and Web of Science databases that employed quantitative analysis, retrieved up to July 2023. Most of the studies indicate that AI leads to cost savings and improved efficiency in ophthalmology. On the other hand, some studies suggest that using AI in healthcare may raise costs for patients, especially when taking into account factors such as labor costs, infrastructure, and patient adherence. Future research should cover a wider range of ophthalmic diseases beyond common eye conditions. Moreover, conducting extensive health economic research, designed to collect data relevant to its own context, is imperative.

2.
Asia Pac J Ophthalmol (Phila) ; 12(6): 537-564, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38079242

RESUMO

The development of minimally invasive glaucoma surgeries (MIGSs) was intended to provide safe and modestly efficacious modalities for early intervention of mild-to-moderate glaucoma, with minimal trauma and rapid recovery. They were mainly ab interno procedures that reduce intraocular pressure by facilitating the aqueous outflow by bypassing the trabecular meshwork resistance, reinforcing the uveoscleral flow via the supraciliary space, and reducing aqueous production by the ciliary body. While the cumulating evidence helps shape the role of the available MIGS, the exponential new development and advancement in this field has expanded the territory of MIGS. Apart from developing subconjunctival MIGS filtration devices (Xen gel stent and PRESERFLO MicroShunt), there is a tendency to revisit the "traditional" MIGS for alternative use and to modify the procedures with consideration of the fundamental aqueous outflow physiology. Combined MIGS has also been suggested, based on the theory that their different mechanisms may provide additive or synergistic effects. The advancement of laser procedures is also promising and could supplement unmet needs along the glaucoma treatment algorithm. This review examines the broad array of MIGS, updates the recent findings, discusses their potential alternative applications, and explores future challenges.


Assuntos
Cirurgia Filtrante , Implantes para Drenagem de Glaucoma , Glaucoma , Humanos , Glaucoma/cirurgia , Pressão Intraocular , Cirurgia Filtrante/métodos , Tonometria Ocular
3.
Arq. bras. oftalmol ; 86(4): 322-329, July-Sep. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1447374

RESUMO

ABSTRACT Purpose: This study aimed to use computational models for simulating the movement of respiratory droplets when assessing the efficacy of standard slit-lamp shield versus a new shield designed for increased clinician comfort as well as adequate protection. Methods: Simulations were performed using the commercial software Star-CCM+. Respiratory droplets were assumed to be 100% water in volume fraction with particle diameter distribution represented by a geometric mean of 74.4 (±1.5 standard deviation) μm over a 4-min duration. The total mass of respiratory droplets expelled from patients' mouths and droplet accumulation on the manikin were measured under the following three conditions: with no slit-lamp shield, using the standard slit-lamp shield, and using our new proposed shield. Results: The total accumulated water droplet mass (kilogram) and percentage of expelled mass accumulated on the shield under the three aforementioned conditions were as follows: 5.84e-10 kg (28% of the total weight of particle emitted that settled on the manikin), 9.14e-13 kg (0.045%), and 3.19e-13 (0.015%), respectively. The standard shield could shield off 99.83% of the particles that would otherwise be deposited on the manikin, which is comparable to 99.95% for the proposed design. Conclusion: Slit-lamp shields are effective infection control tools against respiratory droplets. The proposed shield showed comparable effectiveness compared with conventional slit-lamp shields, but with potentially enhanced ergonomics for ophthalmologists during slit-lamp examinations.


RESUMO Introdução: Os oftalmologistas têm alto risco de contrair a doença do Coronavírus-19 devido à proximidade com os pacientes durante os exames com lâmpada de fenda. Usamos um modelo de computação para avaliar a eficácia das proteções para lâmpadas de fenda e propusemos uma nova proteção ergonomicamente projetada. Métodos: As simulações foram realizadas no software comercial Star-CCM +. Os aerossóis de gotículas foram considerados 100% de água em fração de volume com distribuição de diâmetro de partícula representada por uma média geométrica de 74,4 ± 1,5 (desvio padrão) μm ao longo de uma duração de quatro minutos. A massa total de gotículas de água acumulada no manequim e a massa expelida pela boca do paciente foram medidas em três condições diferentes: 1) Sem protetor de lâmpada de fenda, 2) com protetor padrão, 3) Com o novo protetor proposto. Resultados: A massa total acumulada das gotas de água (kg) e a porcentagem da massa expelida acumulada no escudo para cada uma das respectivas condições foram; 1) 5,84e-10 kg (28% do peso total da partícula emitida que assentou no manequim), 2) 9,14e-13 kg (0,045%), 3,19e-13 (0,015%). O escudo padrão foi capaz de proteger 99,83% das partículas que, de outra forma, teriam se depositado no manequim, o que é semelhante a 99,95% para o projeto proposto. Conclusão: Protetores com lâmpada de fenda são ferramentas eficazes de controle de infecção contra gotículas respiratórias. O protetor proposto mostrou eficácia comparável em comparação com os protetores de lâmpada de fenda convencionais, mas potencialmente oferece uma melhor ergonomia para oftalmologistas durante o exame de lâmpada de fenda.

4.
J Med Internet Res ; 23(8): e24152, 2021 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-34420929

RESUMO

BACKGROUND: Virtual reality, augmented reality, and mixed reality make use of a variety of different software and hardware, but they share three main characteristics: immersion, presence, and interaction. The umbrella term for technologies with these characteristics is extended reality. The ability of extended reality to create environments that are otherwise impossible in the real world has practical implications in the medical discipline. In ophthalmology, virtual reality simulators have become increasingly popular as tools for surgical education. Recent developments have also explored diagnostic and therapeutic uses in ophthalmology. OBJECTIVE: This systematic review aims to identify and investigate the utility of extended reality in ophthalmic education, diagnostics, and therapeutics. METHODS: A literature search was conducted using PubMed, Embase, and Cochrane Register of Controlled Trials. Publications from January 1, 1956 to April 15, 2020 were included. Inclusion criteria were studies evaluating the use of extended reality in ophthalmic education, diagnostics, and therapeutics. Eligible studies were evaluated using the Oxford Centre for Evidence-Based Medicine levels of evidence. Relevant studies were also evaluated using a validity framework. Findings and relevant data from the studies were extracted, evaluated, and compared to determine the utility of extended reality in ophthalmology. RESULTS: We identified 12,490 unique records in our literature search; 87 met final eligibility criteria, comprising studies that evaluated the use of extended reality in education (n=54), diagnostics (n=5), and therapeutics (n=28). Of these, 79 studies (91%) achieved evidence levels in the range 2b to 4, indicating poor quality. Only 2 (9%) out of 22 relevant studies addressed all 5 sources of validity evidence. In education, we found that ophthalmic surgical simulators demonstrated efficacy and validity in improving surgical performance and reducing complication rates. Ophthalmoscopy simulators demonstrated efficacy and validity evidence in improving ophthalmoscopy skills in the clinical setting. In diagnostics, studies demonstrated proof-of-concept in presenting ocular imaging data on extended reality platforms and validity in assessing the function of patients with ophthalmic diseases. In therapeutics, heads-up surgical systems had similar complication rates, procedural success rates, and outcomes in comparison with conventional ophthalmic surgery. CONCLUSIONS: Extended reality has promising areas of application in ophthalmology, but additional high-quality comparative studies are needed to assess their roles among incumbent methods of ophthalmic education, diagnostics, and therapeutics.


Assuntos
Realidade Aumentada , Oftalmologia , Realidade Virtual , Humanos
7.
Ophthalmol Glaucoma ; 3(5): 350-359, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32980037

RESUMO

PURPOSE: To investigate efficacy 1 year after implantation of a novel glaucoma tube shunt, the PAUL Glaucoma Implant (PGI; Advanced Ophthalmic Innovations, Singapore, Republic of Singapore), in the treatment of eyes with refractory glaucoma. DESIGN: Clinical trial. PARTICIPANTS: Glaucoma patients who are recalcitrant to maximum tolerated medical therapy and require tube shunt surgery. METHODS: Interventional cohort study involving consecutive PGIs implanted at 6 international centers between December 1, 2017, and December 1, 2018. All the participants were followed up for 1 year after surgery. MAIN OUTCOME MEASURES: The primary outcome measure was failure, defined prospectively as intraocular pressure (IOP) of more than 21 mmHg or less than 20% reduction from the preoperative baseline on 2 consecutive visits, 3 months or more after surgery; persistent late hypotony, defined as IOP of less than 6 mmHg on 2 consecutive visits after 3 months; additional glaucoma surgery; loss of light perception vision; or removal of the implant for any reason. RESULTS: Of 82 patients enrolled, 74 (74 eyes) completed 12 months of follow-up. The mean age ± standard deviation at enrollment was 62.3±14.7 years, 73.0% were men, and 36.5% had secondary glaucoma. One year after surgery, 4 patients (5.4%) fulfilled the surgical criteria for failure, 68.9% (51/74 eyes) were deemed complete successes, and 93.2% (69/74 eyes) were considered qualified successes. Compared with the medicated preoperative IOP (23.1±8.2 mmHg), the postoperative IOPs at 6 and 12 months were 13.8±4.0 mmHg and 13.2±3.3 mmHg, respectively (P < 0.001). The mean number of IOP-lowering drugs used before surgery and after 12 months of follow-up were 3.3±0.9 and 0.3±0.6, respectively (P < 0.001). Significant postoperative complications included self-limiting shallow anterior chamber (n = 11; 14.9%), hypotony requiring intervention (n = 7; 9.5%), tube shunt occlusion (n = 5; 6.8%), tube exposure (n = 3; 4.1%), and endophthalmitis with resultant loss of vision (n = 1; 1.4%). CONCLUSIONS: The PGI demonstrated comparable efficacy with other currently available implants, with almost three quarters of the enrolled patients with refractory glaucoma achieving complete surgical success after 1 year of follow-up.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma/cirurgia , Pressão Intraocular/fisiologia , Trabeculectomia/métodos , Acuidade Visual , Feminino , Seguimentos , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Tonometria Ocular , Resultado do Tratamento
8.
J Glaucoma ; 29(4): 264-270, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31972595

RESUMO

PRéCIS:: In advanced refractory glaucoma which has failed prior MP3 laser, MP3 Plus is effective in reducing intraocular pressure (IOP) without significant complications. It is also useful as a temporizing procedure before incisional surgery. PURPOSE: To evaluate the efficacy and safety of MP3 Plus, a novel technique using modified micropulse transscleral cyclophototherapy (MPTCP) in eyes with refractory glaucoma or failed MPTCP treatment. METHODS: This is a retrospective interventional case series. In total, 32 consecutive eyes from 29 patients with uncontrolled IOPs who had previous MPTCP or refractory glaucoma underwent MP3 Plus, a modified MPTCP where additional discrete pulses are applied. The main outcome measurement was IOP at 1, 3, 6, and 12 months postprocedure, with success defined as a 20% reduction in baseline IOP, an IOP of 25 mmHg or less, and no need for further reoperation. We collected and analyzed visual acuity, number of glaucoma medications, and complications. RESULTS: The patients had an average of 1.4±0.9 glaucoma procedures before treatment, where 87.5% underwent one or more previous MPTCP with suboptimal response. Of the eyes presenting for follow-up, 51.6% (n=31), 37.0% (n=27), 35.7% (n=28), and 25.9% (n=27) achieved the primary outcome at 1, 3, 6, and 12 months, respectively. Baseline IOP was 33.7±11.6 mmHg (n=32 eyes) and posttreatment IOP at 1, 3, 6, and 12 months were 21.0±9.0 mmHg (n=31; P<0.0001), 26.2±10.8 mmHg (n=25; P<0.0001), 23.2±9.4 mmHg (n=20; P<0.05), and 24.6±9.8 mmHg (n=16; P<0.001), respectively. There was a reduction in glaucoma medications from 3.4±0.8 preoperatively to 2.8±1.2 (n=16; P<0.05) at 12 months. There were no cases of prolonged inflammation or hypotony. CONCLUSIONS: MP3 Plus is effective and safe in lowering IOP in eyes with refractory glaucoma after previous failed MPTCP.


Assuntos
Corpo Ciliar/cirurgia , Glaucoma/cirurgia , Fotocoagulação a Laser/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Lasers Semicondutores/uso terapêutico , Masculino , Pessoa de Meia-Idade , Hipotensão Ocular/fisiopatologia , Hipotensão Ocular/cirurgia , Avaliação de Resultados em Cuidados de Saúde , Procedimentos de Cirurgia Plástica , Reoperação , Estudos Retrospectivos , Esclera/cirurgia , Resultado do Tratamento , Acuidade Visual/fisiologia , Adulto Jovem
9.
J Glaucoma ; 28(8): 697-700, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31095000

RESUMO

PRECIS: Repeated use of the Micropulse P3 (MP3) probe during micropulse transscleral cyclophotocoagulation is associated with an increase in laser output over time. PURPOSE: The purpose of this study was to examine the laser efficacy of the MP3 probe following repeated use. METHODS: This was an observational study carried out using Cyclo G6 Glaucoma Laser System with 6 MP3 laser delivery probes. Each probe was fired for 100 seconds, every 10 minutes until the probe was deactivated. The laser output was measured using a laser power meter. Maximum observed laser power output was also noted. RESULTS: All probes were deactivated after 90 minutes (9 cycles) of use. Mean laser output of all 6 probes was determined, and results suggested an increase in output with time. When examining the differences in total laser output for each cycle, no significant differences were observed for the first 4 cycles, but not for the remaining 5 cycles, wherein the increased laser outputs were found to be significantly different from baseline (cycle 1). CONCLUSION: Findings suggest a possible increase in laser output with repeated use, especially after 4 cycles, and clinicians need to be cautious if they intend to use the probes repeatedly.


Assuntos
Análise de Falha de Equipamento , Glaucoma/cirurgia , Terapia a Laser/instrumentação , Lasers Semicondutores , Equipamentos e Provisões/normas , Humanos , Terapia a Laser/métodos , Terapia a Laser/normas , Lasers Semicondutores/normas , Modelos Lineares , Reprodutibilidade dos Testes , Singapura
10.
Acta Ophthalmol ; 97(1): e57-e63, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30284403

RESUMO

PURPOSE: Develop an algorithm to predict the success of laser peripheral iridotomy (LPI) in primary angle closure suspect (PACS), using pretreatment anterior segment optical coherence tomography (ASOCT) scans. METHODS: A total of 69 eyes with PACS underwent LPI and time-domain ASOCT scans (temporal and nasal cuts) were performed before and after LPI. After LPI, success is defined as one or more angles changed from closed to open. All the pretreatment ASOCT scans were analysed using the Anterior Segment Analysis Program to derive anterior chamber angle (ACA) measurements. The measurements for each angle were ordered along with angle-independent measurements totalling to 42 measurements which serve as features for the prediction algorithm. Two masked glaucoma fellowship-trained ophthalmologists graded the pre-LPI ASOCT scans to determine whether LPI was likely to successful. RESULTS: There were 42 (60.9%) eyes that fulfilled the criteria for success after LPI. Iris concavity, angle recess area (750 µm) and iris concavity ratio showed the highest predictive score and were selected using correlation-based subset selection method. These features were classified into two ('successful' and 'unsuccessful') categories using a Bayes classifier. The algorithm predicted the success of LPI with 79.28% cross validation accuracy, which was superior to the predictive accuracy of the ophthalmologists (kappa 0.497 and 0.636 respectively). CONCLUSION: Using pretreatment ASOCT scans, our algorithm was superior to ophthalmologists in predicting the success of LPI for PACS eyes. This novel algorithm could aid decision making in offering LPI as a prophylaxis for PACS.


Assuntos
Algoritmos , Segmento Anterior do Olho/diagnóstico por imagem , Glaucoma de Ângulo Fechado/cirurgia , Iridectomia/métodos , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Tomografia de Coerência Óptica/métodos , Feminino , Seguimentos , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/fisiopatologia , Gonioscopia , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
11.
J Glaucoma ; 27(8): 733-738, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29916997

RESUMO

PURPOSE: There is a lack of long-term Asian studies on the efficacy and safety of Ahmed glaucoma valve (AGV) implantation. This study seeks to determine the outcomes and complications of AGV implantation in Asians. METHODS: A retrospective review of AGV surgeries performed at a single center in Singapore was conducted. A total of 76 patients with primary and secondary glaucoma who underwent their first AGV surgery from January 1, 2010 to December 31, 2012 were considered for our study. Primary outcomes evaluated were as follows: failure, intraocular pressure, best-corrected visual acuity, number of intraocular pressure (IOP)-lowering medications, and complications. Failure was defined by the following: IOP >21 mm Hg on 2 consecutive visits after 3 months, IOP≤5 mm Hg on 2 consecutive visits after 3 months, reoperation for glaucoma, removal of implant, or loss of light perception vision. RESULTS: Mean follow-up duration was 33.2±6.9 months. There was significant reduction in IOP (mean reduction, 25.9%; P<0.001) and number of IOP-lowering medications (mean reduction, 77.8%; P<0.001) at 3 years. Absolute failure rate was 23.9% at 3 years with no difference between eyes with or without previous trabeculectomy and between eyes with primary or secondary glaucoma. Occurrence of postoperative hyphema was a significant risk factor for failure. The commonest postoperative complications were hyphema and tube exposure. CONCLUSIONS: At 3 years after AGV surgery in Asian eyes, less than one-quarter of the eyes fulfilled the criteria for surgical failure.


Assuntos
Povo Asiático/etnologia , Implantes para Drenagem de Glaucoma , Glaucoma/etnologia , Glaucoma/cirurgia , Complicações Pós-Operatórias , Implantação de Prótese/métodos , Adulto , Idoso , Feminino , Seguimentos , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Singapura/epidemiologia , Tonometria Ocular , Resultado do Tratamento , Acuidade Visual/fisiologia
12.
J Ophthalmol ; 2018: 9824035, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29765780

RESUMO

BACKGROUND: To evaluate the outcome and complications of transscleral suture-fixated posterior chamber intraocular lens (PCIOL) implantation combined with Ahmed glaucoma valve (AGV) surgery in Asian eyes. DESIGN: This was a retrospective study that included 22 eyes from 22 participants. The surgeries were performed at Singapore's National University Hospital. Participants underwent an Ahmed tube surgery, together with transscleral suture-fixated posterior chamber intraocular lens. MAIN OUTCOME MEASURES: Complete success was defined as 6 ≤ intraocular pressure (IOP) ≤ 21 mmHg without medications at the last follow-up visit, with no reoperation required and no progression to no perception of light (NPL). RESULTS: At the last follow-up, there was a significant reduction in mean IOP (22.4 ± 6.5 mmHg versus 13.9 ± 3.9 mmHg; p < 0.001) and mean number of intraocular pressure-lowering medications (2.45 ± 1.30 versus 0.05 ± 0.21; p < 0.001). There was no significant change in visual acuity [1.43 ± 1.21 (LogMAR) versus 1.09 ± 1.31 (p = 0.204)]. Sixteen eyes (72.7%) achieved complete success. The 3 commonest complications were bullous keratopathy, choroidal detachment, and displacement of intraocular lens. CONCLUSION AND RELEVANCE: This technique showed good success for intraocular pressure control and vision preservation. Postoperative complications were relatively common although most were self-limiting. Patients at increased risk of trabeculectomy failure may be suitable for this procedure.

13.
J Med Syst ; 42(6): 107, 2018 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-29704138

RESUMO

Develop an algorithm to predict the success of laser peripheral iridotomy (LPI) in primary angle closure suspect (PACS), using pre-treatment anterior segment optical coherence tomography (ASOCT) scans. A total of 116 eyes with PACS underwent LPI and time-domain ASOCT scans (temporal and nasal cuts) were performed before and 1 month after LPI. All the post-treatment scans were classified to one of the following categories: (a) both angles open, (b) one of two angles open and (c) both angles closed. After LPI, success is defined as one or more angles changed from close to open. In this proposed method, the pre and post-LPI ASOCT scans were registered at the corresponding angles based on similarities between the respective local descriptor features and random sample consensus technique was used to identify the largest consensus set of correspondences between the pre and post-LPI ASOCT scans. Subsequently, features such as correlation co-efficient (CC) and structural similarity index (SSIM) were extracted and correlated with the success of LPI. We included 116 eyes and 91 (78.44%) eyes fulfilled the criteria for success after LPI. Using the CC and SSIM index scores from this training set of ASOCT images, our algorithm showed that the success of LPI in eyes with narrow angles can be predicted with 89.7% accuracy, specificity of 95.2% and sensitivity of 36.4% based on pre-LPI ASOCT scans only. Using pre-LPI ASOCT scans, our proposed algorithm showed good accuracy in predicting the success of LPI for PACS eyes. This fully-automated algorithm could aid decision making in offering LPI as a prophylactic treatment for PACS.


Assuntos
Algoritmos , Glaucoma de Ângulo Fechado/cirurgia , Iridectomia/métodos , Terapia a Laser/métodos , Tomografia de Coerência Óptica/métodos , Idoso , Câmara Anterior/patologia , Feminino , Humanos , Pressão Intraocular , Lasers de Estado Sólido , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
14.
J Glaucoma ; 26(7): 619-625, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28448294

RESUMO

PURPOSE: To study the distribution of macular ganglion cell-inner plexiform layer (GC-IPL) thickness and peripapillary retinal nerve fiber layer (RNFL) thickness in children with refractive errors. MATERIALS AND METHODS: Two hundred forty-three healthy eyes from 139 children with refractive error ranging from -10.00 to +5.00 D were recruited from the National University Hospital Eye Surgery outpatient clinic. After a comprehensive ocular examination, refraction, and axial length (AL) measurement (IOLMaster), macular GC-IPL and RNFL thickness values were obtained with a spectral domain Cirrus high definition optical coherence tomography system (Carl Zeiss Meditec Inc.). Only scans with signal strength of >6/10 were included. Correlation between variables was calculated using the Pearson correlation coefficient. A multivariate analysis using mixed models was done to adjust for confounders. RESULTS: The mean spherical equivalent refraction was -3.20±3.51 D and mean AL was 24.39±1.72 mm. Average, minimum, superior, and inferior GC-IPL were 82.59±6.29, 77.17±9.65, 83.68±6.96, and 81.64±6.70 µm, respectively. Average, superior, and inferior peripapillary RNFL were 99.00±11.45, 123.20±25.81, and 124.24±22.23 µm, respectively. Average, superior, and inferior GC-IPL were correlated with AL (ß=-2.056, P-value 0.000; ß=-2.383, P-value 0.000; ß=-1.721, P-value 0.000), but minimum GC-IPL was not (ß=-1.056, P-value 0.115). None of the RNFL parameters were correlated with AL. CONCLUSIONS: This study establishes normative macular GC-IPL and RNFL thickness in children with refractive errors. Our results suggest that high definition optical coherence tomography RNFL parameters and minimum GC-IPL are not affected by AL or myopia in children, and therefore warrants further evaluation in pediatric glaucoma patients.


Assuntos
Fibras Nervosas , Disco Óptico/anatomia & histologia , Erros de Refração/complicações , Células Ganglionares da Retina/citologia , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Pressão Intraocular , Masculino , Estudos Prospectivos , Valores de Referência , Refração Ocular/fisiologia , Tomografia de Coerência Óptica/métodos , Acuidade Visual/fisiologia
15.
Jpn J Ophthalmol ; 61(3): 245-252, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28188405

RESUMO

PURPOSE: To determine the long-term outcomes of 2-site phacoemulsification combined with fornix-based trabeculectomy using mitomycin C (MMC) for primary angle-closure glaucoma (PACG) and primary open-angle glaucoma (POAG) in an Asian population. METHODS: We reviewed the records of all patients with POAG or PACG who underwent phacoemulsification with trabeculectomy using MMC from January 2008 through December 2010 in a tertiary ophthalmology unit in Singapore. The primary outcome measure was cumulative success rates defined as complete [intraocular pressure (IOP) <21, 18, 15 mmHg without medication] and qualified (IOP <21, 18, 15 mmHg with at least 1 medication) success. RESULTS: In total, 168 eyes (110 POAG and 58 PACG) were included (43.5% female; mean age ± SD, 68.3 ± 8.2 years). The respective 3-year qualified success rates were 88.4, 79.3, and 52.5% for IOP <21, 18, and 15 mmHg. The corresponding complete success rates were 79.0, 70.9, and 51.1%. The mean 3-year postoperative IOP was 14.5 ± 4.4 mmHg, and the IOP reduction was significantly greater for PACG than for POAG eyes (P = 0.006). After surgery, the mean number of medications was significantly reduced and visual acuity, significantly improved (both P < 0.001). Occurrence of postoperative complications, higher number of topical medications, younger age, and presence of diabetes mellitus were significant risk factors for surgical failure. CONCLUSION: Two-site phacoemulsification combined with fornix-based trabeculectomy using MMC is a good surgical approach for Asian eyes with concomitant mild-to-moderate primary glaucoma and cataracts.


Assuntos
Catarata/terapia , Glaucoma de Ângulo Fechado/terapia , Glaucoma de Ângulo Aberto/terapia , Pressão Intraocular/fisiologia , Mitomicina/administração & dosagem , Facoemulsificação/métodos , Trabeculectomia/métodos , Idoso , Catarata/complicações , Catarata/epidemiologia , Feminino , Seguimentos , Glaucoma de Ângulo Fechado/complicações , Glaucoma de Ângulo Fechado/epidemiologia , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/epidemiologia , Humanos , Incidência , Masculino , Inibidores da Síntese de Ácido Nucleico/administração & dosagem , Estudos Retrospectivos , Singapura/epidemiologia , Fatores de Tempo , Resultado do Tratamento , Acuidade Visual
16.
Asia Pac J Ophthalmol (Phila) ; 4(5): 293-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26288346

RESUMO

PURPOSE: An anonymous Web-based survey was performed to assess the current practices, preferences, and complications of aesthetic procedures encountered by oculofacial surgeons in the Asia-Pacific. Results were compared with a similar study carried out in 2007 among members of the American Society of Ophthalmic Plastic and Reconstructive Surgery (ASOPRS). DESIGN: This was a cross-sectional survey study. METHODS: The study survey was sent out via e-mail to 131 oculofacial surgeons in 14 countries in the Asia-Pacific. Survey questions included the demographics of survey respondents, practices, preferences, and complications of aesthetic procedures encountered by the surgeons. RESULTS: Seventy-four respondents (56.5%) attempted the survey between May and December 2012. Only completed surveys (43 surveys) were included in our analysis. Eighty-six percent of respondents performed aesthetic procedures in their practice. The top 3 most common nonsurgical procedures reported were injection of botulinum toxin (94.1% of respondents), tissue fillers (61.8%), and skin resurfacing (11.8%), whereas the top 3 most common surgical procedures reported were blepharoplasty (100% of respondents), brow lift (94.6%), and midface lift (29.7%). CONCLUSIONS: The majority of our study respondents performed aesthetic procedures in their practice. The percentage of practices that comprised aesthetics services was lower than that seen in the ASOPRS study. The percentage of respondents who performed injection of botulinum toxin, tissue fillers, brow lifts, and thread lifts were similar to those in the ASOPRS study; however, the percentage of respondents who performed ablative skin resurfacing was much lower.


Assuntos
Procedimentos Cirúrgicos Oftalmológicos/métodos , Padrões de Prática Médica/estatística & dados numéricos , Cirurgia Plástica/estatística & dados numéricos , Ásia , Blefaroplastia , Toxinas Botulínicas Tipo A/administração & dosagem , Estudos Transversais , Preenchedores Dérmicos/administração & dosagem , Pesquisas sobre Atenção à Saúde , Humanos , Oceano Pacífico , Ritidoplastia/estatística & dados numéricos , Inquéritos e Questionários
17.
Indian J Ophthalmol ; 63(12): 895-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26862093

RESUMO

OBJECTIVE: To compare the incidence of upper eyelid blepharoptosis after combined phacotrabeculectomy with mitomycin C and phacoemulsification surgeries and the relationship of bleb morphology to the incidence of ptosis. DESIGN: Retrospective observation study. PARTICIPANTS: We included 46 patients after combined phacotrabeculectomy and 44 patients with phacoemulsification in the former group, and all eyes underwent a standardized two-site surgery with intra-operative mitomycin C. MATERIALS AND METHODS: Postoperative ptosis was defined as a reduction of upper marginal reflex distance 2 mm in the operated eye compared to the fellow eye. Trabeculectomy bleb measurements were carried out using anterior segment optical coherence tomography (Visante™, Carl Zeiss Meditec, Dublin, CA, USA) which included bleb height and total area of the bleb. RESULTS: There were 8 eyes (17.4%) and 5 eyes (11.4%) with postoperative ptosis in the phacotrabeculectomy and phacoemulsification groups, respectively (P = 0.342). In multivariate regression analysis, reduced total bleb area was significantly associated with upper eyelid ptosis after adjusting for age, gender, and type of anesthesia. The trend seemed to show that increased bleb height was also associated with ptosis, but this did not reach statistical significance. CONCLUSIONS: Incidence of persistent ptosis after phacoemulsification combined with trabeculectomy and mitomycin C is similar compared to stand alone phacoemulsification surgery in a multiethnic Asian population. Bleb morphology may play an important role in postoperative ptosis development and should be considered in the evaluation of upper eyelid blepharoptosis.


Assuntos
Blefaroptose/epidemiologia , Mitomicina/administração & dosagem , Facoemulsificação/métodos , Complicações Pós-Operatórias , Trabeculectomia/métodos , Idoso , Alquilantes/administração & dosagem , Blefaroptose/diagnóstico , Catarata/complicações , Terapia Combinada , Feminino , Glaucoma/complicações , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia de Coerência Óptica
19.
Orbit ; 33(5): 319-25, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25121573

RESUMO

AIM: A web-based anonymous survey was performed to evaluate practice preferences in the management of Graves' orbitopathy amongst oculofacial surgeons in the Asia-Pacific region. METHODS: A questionnaire with contentious topics in Graves' orbitopathy was sent out via email to oculofacial surgeons in 14 countries within Asia-Pacific between May to December 2012. RESULTS: A response rate of 25.2% to 34.6% was achieved (32-44 of 127 participants). 61.0% of respondents encountered Graves' orbitopathy commonly in their practice. The more common causes of vision loss in Graves' orbitopathy included dysthyroid optic neuropathy (67.5%) and exposure keratopathy (15.0%). The clinical activity score was the most popular grading system for assessing Graves' orbitopathy. The preferred non-surgical therapeutic approaches included intravenous pulsed methylprednisolone (79.5%), oral steroids (56.4%), orbital radiation (12.8%), steroid-sparing immunosuppressants (10.3%) and watchful observation (7.7%). Thyroid orbital decompression was uncommonly or rarely performed by respondents. Orbital surgical decompression was most commonly performed via the two-wall technique (73.5%) and most respondents performed fat decompression (69.4%). Post-operatively, the most common complications include under correction (45.5%) and diplopia (42.4%). CONCLUSION: We report the results of the first survey on the management of Graves' orbitopathy amongst oculofacial surgeons in Asia-Pacific. Our respondents practice preferences reflected the Graves' orbitopathy management consensus statement by the European group on Graves' orbitopathy in 2008.


Assuntos
Oftalmopatia de Graves/terapia , Oftalmologia/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Cirurgia Plástica/estatística & dados numéricos , Ásia , Inquéritos Epidemiológicos , Humanos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Procedimentos Cirúrgicos Oftalmológicos/estatística & dados numéricos , Oceano Pacífico , Inquéritos e Questionários
20.
Can J Ophthalmol ; 49(3): 249-55, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24862770

RESUMO

OBJECTIVE: To examine the reliability of inexperienced observers in plotting optic disc contours on Heidelberg retinal tomography images before and after training. DESIGN: Observational study. PARTICIPANTS: One hundred eyes that were randomly selected from the Singapore Indian Eye Study. METHODS: Both eyes of subjects were imaged with Heidelberg Retina Tomograph 3 (HRT-3; Heidelberg Engineering, Heidelberg, Germany). Optic disc contours were plotted on the same images by 2 new observers on 2 separate occasions, before and after 2-hour standardized training on the skills and tools available to accurately identify and delineate optic disc contours. These plottings were compared with an experienced, trained glaucoma expert (gold standard). Agreement and variability were analyzed by interclass correlation tests and Bland-Altman plots. RESULTS: A total of 182 images (18 excluded because of poor quality) from 89 Indian subjects were included. The mean age was 53.27 ± 7.25 years and 54.8% were male. There was moderate-to-high agreement between pretraining (both new observers) and experienced observer's results (interclass correlation values range, 0.76-0.99). The interclass correlation improved for all the HRT-3 parameters after the 2 new observers were adequately trained. Comparing the interclass correlation values before and after training, the differences for mean retinal nerve fibre layer thickness for Observer 1 and all the HRT-3 parameters for Observer 2 were statistically significant. CONCLUSIONS: This study shows that it is easy to train a new inexperienced observer to plot optic disc contours on HRT images, which translates into improved and acceptable interobserver variability and agreement.


Assuntos
Glaucoma/diagnóstico , Oftalmologia/educação , Oftalmoscópios , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Fotogrametria/instrumentação , Competência Clínica , Estudos Transversais , Feminino , Glaucoma/etnologia , Humanos , Índia/etnologia , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Doenças do Nervo Óptico/etnologia , Reprodutibilidade dos Testes , Singapura/epidemiologia , Tomografia , População Branca/etnologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA